Description

Portwest S781 Anti-Static Bizflame Flame-Resistant Rain

This waterproof trouser is ideal for wet conditions where extra warmth is required. Elasticated FR braces keep the trouser in place when bending and stretching while the raised back provides extra warmth and protection.

RIS-3279-TOM ISSUE 1 (ORANGE ONLY)

Features / Fabric

Portwest S781 Features

  • Flame resistant treated waterproof fabric prevents water penetration
  • FR cotton lined for added warmth and comfort
  • Zipped ankles for easy fitting over work boots
  • Back waist buggy for added protection
  • Ergonomic quick release buckle
  • Adjustable straps for a secure fit
  • Anti-static
  • Premium sew on flame resistant reflective tape
  • Breathable fabric to draw moisture away from the body keeping the wearer cool, dry and comfortable
  • Taped seams to provide additional protection
  • Fully elasticated waistband for ultimate wearer comfort
  • CE certified
  • CE-CAT III

Portwest S781 Fabric 

  • Shell Fabric: Bizflame Rain: 98% Polyester, 2% Antistatic Carbon Fibre, Breathable, PU Coated 250g
  • Lining Fabric: 100% Cotton Flame Resistant Lining 170g

Fabric Information:

Bizflame Rain Fabric combines a 98% Polyester and 2% anti-static carbon fibre 250g, this breathable fabric offers maximum protection to a range of International Standards.

Technical Info

Product Technical Information

Standards

  • EN ISO 14116 Index 3
  • EN 1149 -5
  • EN 13034 Type PB [6]
  • EN ISO 20471 Class 1
  • RIS 3279 TOM Issue 2 (Orange Only)
  • EN 343 Class 3:3 X

Washcare

Documentation

EN ISO 14116: 2008

Protective Clothing Against Limited Flame Spread Materials and Material Aseemblies

This standard specifies the performance requirements for the limited flame spread properties of materials, material assemblies and protective clothing in order to reduce the possibility of the clothing burning and thereby itself constituting a hazard. Additional requirements for clothing are also specified.

Protective clothing complying with this standard is intended to protect workers against occasional and brief contact with small igniting flames in circumstances where there is no significant flame hazard and without the presence of another type of heat.

 

EN1149 -5

Protective Clothing against the Thermal Hazards of an Electric Arc

This European Standard is part of a series of standards for test methods and requirements for electrostatic properties of protective clothing. The standard specifies material and design requirements for garments used as part of a total earthed system, to avoid incendiary discharges. The requirements may not be sufficient in oxygen enriched flammable atmospheres. This standard is not applicable for protection against mains voltages.

EN 1149 consists of the following parts:

EN 1149-1: Test Method for measurement of surface resistivty.

EN 1149-2: Test Method for measurement of the electrical resistance through a material (Vertical resistance)

EN 1149-3: Test Methods for measurement of charge decay.

EN 1149-4: Garment Test (under development)

EN 1149-5: Material Performance and design requirements.

Electrostatics dissipative protective clothing shall be able to permanently cover all non-complying materials during normal use. Conductives parts (Zips, Buttons etc) are permitted provided they are cover by the outermost material when in use.

EN 13034:2005

Protective Clothing Against Liquid Chemicals

Performance requirements for chemical protective clothing offering limited protective performance against liquid chemicals (Type 6 and Type PB [6] equipment). This stamdard specifies the minimum requirements for limiter use and re-useable limited performance chemical protective clothing. Limited performance chemical protective clothing is intended for use in cases of a potential exposure to a light spray, liquid aerosols or low pressure, low volume splashes, against which a complete liquid permeation barrier (at a molecular level) is not required.

The Standard covers both chemical protective suits (Type 6) and partial body protection (Type PB [6]).

Type 6 suits are tested using a mist or fine spray of water with a dye added to aid the assessment of leakage. The test subject wears an absorbent suit underneath the one to be tested, which absorbs any leaks and is stained by the dye.

Success or failure is determined by measuring the total area of any stains on three suits and comparing this with the requirement. A range of other tests is specified, including resistance to abrasion, tear strength, tensile strength, resistance to puncture, resistance to ignition, resistance to penetration by liquid chemicals and seam strength. In the test for liquid chemical repellency and resistance to penetration by liquid chemicals, a bank of four test chemicals is given in the standard although the requirement is that the suit material demonstrates adequate repellency and resistance to penetration against one chemical from the list.

EN ISO 20471

This International Standard Specifies requirements for high visibility clothing, which is capable of visually signalling the user’s presence. The high visibility clothing is intended to provide conspicuity of the wearer in any light condition when viewed by the operators of vehicles or other mechanised equipment during daylight conditions and under illumination of headlights in the dark.

High Visibility clothing has a fluorescent surface, combined with reflective material that meets certification requirements in 3 different classes:

Class 3: Highest Level

Highest Level of protection – required for any persons working on or near motorways/dual carriageways or airports. Must incorporate a minimum of 0.80m sq of background materials and 0.20m sq of retro-reflective materials. (4 metres of 5cm wide reflective tape)

Class 2 – Intermediate level

Required for any person working on or near A and B Roads, also for delivery drivers. Must incorporate a minimum of 0.50m sq of background material and 0.13m sq of retro-reflective material. (2.60 metres of 5cm wide reflective tape)

Class 1: Minimum level

Minimum level of protection required for any persons working on a private road or to be sed in conjunction with a higher classed garment. Must incorporate a minimum of 0.14m sq of background material and 0.10m sq of retro-reflective material. (2 metres of 5cm wide reflective tape)

EN 343 – Protective Clothing, Protection Against Rain

EN 343 is the harmonised European standard that applies to garments worn in adverse weather conditions. It specifies the characteristics of protective clothing against the influence of foul weather, wind and coll above –5 Degrees. The standard provides for two parameters: (Example - Class 3:1)

X (3) = Waterproofness (3 Levels) 3 is the highest

Y = (1) Breathable Properties (3 Levels) 3 is the highest