Description

Portwest MV71Portwest MV71 Modaflame Flame Resistant

The Portwest Modaflame MV71 Rain Multi Norm Arc Trouser gives full protection against a range of standards and is packed with features. With a zip off function at the back, the bib can be removed completely to turn it into a trouser which adds to its overall versatility. FR reflective tape enhances visibility whilst contrast knee panels and hem protect against dirt.

     

Features / Fabric

Portwest MV71 Features

  • Protection against radiant, convective and contact heat
  • Lightweight, waterproof fabric with taped seams prevents water penetration
  • Zip-off back turns this bib into a trouser for added versatility
  • Adjustable hem to accommodate all leg lengths
  • Adjustable straps with durable buckle closure
  • Pre-bent knees allow for increased freedom of movement
  • Internal kneepad pockets for better appearance
  • D-ring for keys or ID cards
  • Anti-static
  • Premium sew on flame resistant reflective tape
  • Taped seams to provide additional protection
  • FR cotton lined for added warmth and comfort
  • Flame resistant button and zip
  • 4 pockets for ample storage
  • Contrast colouring for added style
  • CE certified
  • CE-CAT III
  • Knee pad pockets to facilitate knee pads

Shell Fabric 

  • Modaflame Rain+ HV: 98% Polyester, 2% Carbon Fibre, PU Coated, bonded to 60% Modacrylic, 40% Cotton 350g

Lining Fabric 

  • 100% Cotton Flame Resistant Lining 170g

Modaflame Fabric

  • Constructed from an inherently fire resistant yarn of 60% modacrylic, 39% cotton and 1% carbon fibre. Tested to exceed the required EN Standards, the Modaflame Knit range is strong, durable and highly innovation. This fabric has the ability to withstand heat and flame and protect against the danger caused by static electricity and flame. These inherent flame resistant properties will not diminish with repeated washing.
Technical Info

Product Technical Information

Standards

  • EN ISO 11612 A1 + A2, B1, C1, E3, F1
  • EN ISO 11611 Class 2 A1+A2
  • EN 1149 -5
  • IEC 61482-2 IEC 61482-1-2 APC 2
  • IEC 61482-2 IEC 61482-1-1 ELIM 32 CAL/CM²
  • EN 13034 Type 6
  • EN ISO 20471 Class 2
  • RIS 3279 TOM Issue 2 (Orange Only)
  • EN 343 Class 3:1 X

Washcare

Documentation

EN ISO 11612:2008

Protective Clothing Against Heat and Flame

The Performance requirements set out in this international standard are applicable to garment, which could be worn for a wide range of end uses, where the is a need for clothing with limited flame spread properties and where the used can be exposed to radiant, convective or contact heat or molton metal splashes.

This test uses standard methods and conditions to predict the performance of fabric/garment in the event of contact with heat or flames. Garment features such as seams, closures and logos must be tested as well as the fabric. Tests must be carried out on pre=treated components according to the manufacturers care label.

Specific Testing is listed below:

  • Dimensional Charge
  • Limited Flame Spread (A1+A2)*
  • Convective Heat (B) – 3 Levels
  • Radiant Heat (C) - 4 Levels
  • Molten Aluminium Splash (D) – 3 Levels
  • Molten Iron Splash E - 3 Levels
  • Contact Heat (F) – 3 Levels (Temp 250 Degrees Celcius)
  • Heat Resistance at a temperature of 180 Degrees Celcius
  • Tensile Strength Must meet a minimum of 300N
  • Tear Strength must meet a minimum of 15N
  • Bursting Strength
  • Seam Strength

Garment Design requires that coverage must be provided from the neck to the wrist and to the ankles.

Optional Testing includes water vapour resistance and manikin testing for overall burn prediction.

*This test must be carried out on fabric and seams.

 

EN ISO 11611: 2007

Protective Clothing for Use in Welding and Allied Processes

The International standard specifies minimum basic safety requirements and test methods for protective clothing for use in welding and allied processes (Excluding Hand Protection).

The International Standard Specifies two classes with specific performance requirements:

Class 1 is protection against less hazardous welding techniques and situations causing lower levels of spatter and radiant heat.

Class 2 is protection against more hazardous welding techniques and situations causing higher levels of spatter and radiant heat.

EN ISO 11611 requires that protective suits completely cover the upper and lower torso, neck, arms and legs. There are a number of other design requirements which must be followed to prevent molten droplets lodging anywhere on the garment.

Testing must be carried out on pre-treated components according to the manufacturers care label.

  • Tensile Strength (must meet a minimum of 400N)
  • Tear Strength (Must meet a minimum of 20N)
  • Bursting Strength
  • Seam Strength
  • Dimensional Charge
  • Requirements of Leather
  • Limited Flame Spread (A1+A2)*
  • Molten Droplets
  • Heat Transfer (Radiation)
  • Electrical Resistance

*This test must be carried out on the fabric and seams.

 

EN1149 -5

Protective Clothing against the Thermal Hazards of an Electric Arc

This European Standard is part of a series of standards for test methods and requirements for electrostatic properties of protective clothing. The standard specifies material and design requirements for garments used as part of a total earthed system, to avoid incendiary discharges. The requirements may not be sufficient in oxygen enriched flammable atmospheres. This standard is not applicable for protection against mains voltages.

EN 1149 consists of the following parts:

EN 1149-1: Test Method for measurement of surface resistivty.

EN 1149-2: Test Method for measurement of the electrical resistance through a material (Vertical resistance)

EN 1149-3: Test Methods for measurement of charge decay.

EN 1149-4: Garment Test (under development)

EN 1149-5: Material Performance and design requirements.

Electrostatics dissipative protective clothing shall be able to permanently cover all non-complying materials during normal use. Conductives parts (Zips, Buttons etc) are permitted provided they are cover by the outermost material when in use.

 

IEC 61482-2: 2009

Protective Clothing Against The Thermal Hazards of An Electric Arc

This standard specifies requirements and test methods applicable to materials and garments for protective clothing against the thermal effects of an electric arc event. An electric arc is a continuous electric discharge of high current between conductors generating very bright light and intensive heat.

Two international test methods have been developed to provide information on the resistance of clothing to the thermal effects of electric arcs. Each method gives different information. To comply with our standard either or both tests must be carried out.

Box Method EN 61482-1-2

The fabric/garment is exposed to an electric arc confined in a specific box with a specific electrode arrangement for 0.5 seconds. Class 1 is to the current of 4kA arc, Class 2 is to a current 7 kA arc. Test conditions for Class 1 and 2 try to stimulate typical exposure conditions for a short circuit current of 4kA and 7kA respectively.

Open Arc Method EN61482-1-1

This test method aims to establish the ATPV (Arc Thermal Performance Value) of Ebt (Energy Breakopen Threshold) of a fabric. The APTV is the amount of energy required to cause a 2nd degree burn through the material prior to breakopen (50% probability). The EBT is the amount of energy where the material breaks-open (50% probability). This is normally the upper thermal limit of the fabric where the fibres are damaged and material loses mechanical strength, Both APTV and Ebt are expressed in calories per cm2.

 

EN ISO 20471

This International Standard Specifies requirements for high visibility clothing, which is capable of visually signalling the user’s presence. The high visibility clothing is intended to provide conspicuity of the wearer in any light condition when viewed by the operators of vehicles or other mechanised equipment during daylight conditions and under illumination of headlights in the dark.

High Visibility clothing has a fluorescent surface, combined with reflective material that meets certification requirements in 3 different classes:

Class 3: Highest Level

Highest Level of protection – required for any persons working on or near motorways/dual carriageways or airports. Must incorporate a minimum of 0.80m sq of background materials and 0.20m sq of retro-reflective materials. (4 metres of 5cm wide reflective tape)

Class 2 – Intermediate level

Required for any person working on or near A and B Roads, also for delivery drivers. Must incorporate a minimum of 0.50m sq of background material and 0.13m sq of retro-reflective material. (2.60 metres of 5cm wide reflective tape)

Class 1: Minimum level

Minimum level of protection required for any persons working on a private road or to be sed in conjunction with a higher classed garment. Must incorporate a minimum of 0.14m sq of background material and 0.10m sq of retro-reflective material. (2 metres of 5cm wide reflective tape)