Portwest FR18 Flame Resistant Anti-Static Balaclava

Portwest
£15.77 (£18.92 inc vat)
Please select options to view stock level
Weight
121 g
1,677 Stock available
+

Add more items to your order for greater discounts.

1+
£15.77
12+
£15.38
SAVE 2.5%
24+
£14.98
SAVE 5%
60+
£14.59
SAVE 7.5%
108+
£14.19
SAVE 10%
 
Description

Portwest Anti-Static Modaflame Flame Resistant Knit Range

Ideal for cooler conditions to keep the head and neck warm, The ribbed fabric allows for a snug comfortable fit. Wear with FR10, FR11 or FR12.

ONE SIZE ONLY

Features / Fabric

Modaflame

Constructed from an inherently fire resistant yarn of 60% modacrylic, 39% cotton and 1% carbon fibre. Tested to exceed the required EN Standards, the Modaflame Knit range is strong, durable and highly inoovation. This fabric has the ability to withstand heat and flame and protect against the danger caused by static electricity and flame. These inherent flame resistant properties will not diminish with repeated washing.

Fabric:

Modaflame Knit 200g

Features:

  • CE certified
  • Inherent flame resistant qualities will not diminish with washing
  • Protection against radiant
  • convective and contact heat
  • ARC1 (previously HRC1)
  • Anti-static
  • 50+ UPF rated fabric to block 98% of UV rays
  • High cotton content for superior comfort
Technical Info

Product Technical Information

EN ISO 11612:2008

Protective Clothing Against Heat and Flame

The Performance requirements set out in this international standard are applicable to garment, which could be worn for a wide range of end uses, where the is a need for clothing with limited flame spread properties and where the used can be exposed to radiant, convective or contact heat or molton metal splashes.

This test uses standard methods and conditions to predict the performance of fabric/garment in the event of contact with heat or flames. Garment features such as seams, closures and logos must be tested as well as the fabric. Tests must be carried out on pre=treated components according to the manufacturers care label.

Specific Testing is listed below:

  • Dimensional Charge
  • Limited Flame Spread (A1+A2)*
  • Convective Heat (B) – 3 Levels
  • Radiant Heat (C) - 4 Levels
  • Molten Aluminium Splash (D) – 3 Levels
  • Molten Iron Splash E - 3 Levels
  • Contact Heat (F) – 3 Levels (Temp 250 Degrees Celcius)
  • Heat Resistance at a temperature of 180 Degrees Celcius
  • Tensile Strength Must meet a minimum of 300N
  • Tear Strength must meet a minimum of 15N
  • Bursting Strength
  • Seam Strength

Garment Design requires that coverage must be provided from the neck to the wrist and to the ankles.

Optional Testing includes water vapour resistance and manikin testing for overall burn prediction.

*This test must be carried out on fabric and seams.

 

EN1149 -5

Protective Clothing against the Thermal Hazards of an Electric Arc

This European Standard is part of a series of standards for test methods and requirements for electrostatic properties of protective clothing. The standard specifies material and design requirements for garments used as part of a total earthed system, to avoid incendiary discharges. The requirements may not be sufficient in oxygen enriched flammable atmospheres. This standard is not applicable for protection against mains voltages.

EN 1149 consists of the following parts:

EN 1149-1: Test Method for measurement of surface resistivty.

EN 1149-2: Test Method for measurement of the electrical resistance through a material (Vertical resistance)

EN 1149-3: Test Methods for measurement of charge decay.

EN 1149-4: Garment Test (under development)

EN 1149-5: Material Performance and design requirements.

Electrostatics dissipative protective clothing shall be able to permanently cover all non-complying materials during normal use. Conductives parts (Zips, Buttons etc) are permitted provided they are cover by the outermost material when in use.

 

IEC 61482-2: 2009

Protective Clothing Against The Thermal Hazards of An Electric Arc

This standard specifies requirements and test methods applicable to materials and garments for protective clothing against the thermal effects of an electric arc event. An electric arc is a continuous electric discharge of high current between conductors generating very bright light and intensive heat.

Two international test methods have been developed to provide information on the resistance of clothing to the thermal effects of electric arcs. Each method gives different information. To comply with our standard either or both tests must be carried out.

Box Method EN 61482-1-2

The fabric/garment is exposed to an electric arc confined in a specific box with a specific electrode arrangement for 0.5 seconds. Class 1 is to the current of 4kA arc, Class 2 is to a current 7 kA arc. Test conditions for Class 1 and 2 try to stimulate typical exposure conditions for a short circuit current of 4kA and 7kA respectively.

Open Arc Method EN61482-1-1

This test method aims to establish the ATPV (Arc Thermal Performance Value) of Ebt (Energy Breakopen Threshold) of a fabric. The APTV is the amount of energy required to cause a 2nd degree burn through the material prior to breakopen (50% probability). The EBT is the amount of energy where the material breaks-open (50% probability). This is normally the upper thermal limit of the fabric where the fibres are damaged and material loses mechanical strength, Both APTV and Ebt are expressed in calories per cm2.

SKU
FR18NAR
Product Code
FR18
Brand

Payment & Security

Payment methods

VisaMasterCardPayPalApple Pay

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Verified Customer Reviews From Across the Site